Rigol DS1204B Specifiche Pagina 70

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 152
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 69
RIGOL Command Systems
Programming Guide for DS1000B Series
2-58
1. :MEASure:CLEar
Command Format:
:MEASure:CLEar
Function:
The command clears the current measurement parameters.
2. :MEASure:VPP?
Command Format:
:MEASure:VPP? [<source>]
Function:
The command measures the Peak-Peak value of signal from <source>. The
<source> may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.
NOTE: <>” in <source> indicates the source is the parameter that must be set in the
commond; and “[ ]” indicates the parameter can be set or not set according to your demand.
The followings are the same, dont repeat. Please refer to chapter 1 Symbol Description
about the related explanations.
Returned Format:
The query returns as 5.280e000, and the unit is V.
3. :MEASure:VMAX?
Command Format:
:MEASure:VMAX? [<source>]
Function:
The command measures the maximum of signal from <source>. The <source>
may be CHANnel1, CHANnel2, CHANnel3 or CHANnel4.
Returned Format:
The query returns as 2.640e000, and the unit is V.
Vedere la pagina 69
1 2 ... 65 66 67 68 69 70 71 72 73 74 75 ... 151 152

Commenti su questo manuale

Nessun commento