2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-163
:MEASure:FTIMe
Syntax 1
:MEASure:FTIMe <chan>
Description 1
Enable the fall time measurement function of the specified channel.
Syntax 2
:MEASure:FTIMe? <chan>
Description 2
Enable the fall time measurement function of the specified channel and return the measurement result
(the unit is s).
Parameter
Name Type Range Default
<chan> Discrete {CHANnel1|CHANnel2|MATH} --
Return Format
The query returns the fall time measurement result in scientific notation. When the measurement result is
invalid, the query returns 9.9e37.
Example
:MEASure:FTIMe CHANnel1
:MEASure:FTIMe? CHANnel1
You can use the following commands to enable the fall time measurement function of the specified
channel and the statistic function of the measurement results as well as query the statistic maximum
value, minimum value, current value, average value and standard deviation of the fall time measurement
results.
:MEASure:FTIMe:SMAXimum
:MEASure:FTIMe:SMINimum
:MEASure:FTIMe:SCURrent
:MEASure:FTIMe:SAVerage
:MEASure:FTIMe:SDEViation