RIGOL
© 2008 RIGOL Technologies, Inc.
Programming Guide for DM3000 Series
Explanations:
To set the measurement range of DC current and the resolution at the same time.
The measure mode will be changed into manual when setting range.
The table 2-4 indicates the current ranges and the resolutions.
Table 2- 4 The DC current ranges and their resolutions
Example:
To set the DC current range as 10.0A:
:measure:current:DC□MAX or :measure:current:DC□4
21. :measure:current:DC:range?
Syntax:
:measure:current:DC:range?
Function:
The command queries the measure range of DC current.
Return Format:
The query returns the current range parameter: 0、1、2、3 or 4.(see Table 2- 4)
22. :measure:current:DC:digit
Syntax:
:measure:current:DC:digit?
:measure:current:DC:digit□{INC|DEC|5|6|7}
Function:
Commenti su questo manuale